@article{ACS17045,
author = {Yuanjia Zhu and Matthew H. Park and Pearly K. Pandya and Charles J. Stark and Danielle M. Mullis and Sabrina K. Walsh and Joo Young Kim and Catherine A. Wu and Basil M. Baccouche and Seung Hyun Lee and Abakar S. Baraka and Hyunchel Joo and Shin Yajima and Stefan Elde and Y. Joseph Woo},
title = {Biomechanics and clinical outcomes of various conduit configurations in valve sparing aortic root replacement},
journal = {Annals of Cardiothoracic Surgery},
volume = {12},
number = {4},
year = {2023},
keywords = {},
abstract = {Background: Several conduit configurations, such as straight graft (SG), Valsalva graft (VG), anticommissural plication (ACP), and the Stanford modification (SMOD) technique, have been described for the valve-sparing aortic root replacement (VSARR) procedure. Prior ex vivo studies have evaluated the impact of conduit configurations on root biomechanics, but the mock coronary artery circuits used could not replicate the physical properties of native coronary arteries. Moreover, the individual leaflet’s biomechanics, including the fluttering phenomenon, were unclea
Methods: Porcine aortic roots with coronary arteries were explanted (n=5) and underwent VSARR using SG, VG, ACP, and SMOD for evaluation in an ex vivo left heart flow loop simulator. Additionally, 762 patients who underwent VSARR from 1993 through 2022 at our center were retrospectively reviewed. Analysis of variance was performed to evaluate differences between different conduit configurations, with post hoc Tukey’s correction for pairwise testing.
Results: SG demonstrated lower rapid leaflet opening velocity compared with VG (P=0.001) and SMOD (P=0.045) in the left coronary cusp (LCC), lower rapid leaflet closing velocity compared with VG (P=0.04) in the right coronary cusp (RCC), and lower relative opening force compared with ACP (P=0.04) in the RCC. The flutter frequency was lower in baseline compared with VG (P=0.02) and in VG compared with ACP (P=0.03) in the LCC. Left coronary artery mean flow was higher in SG compared with SMOD (P=0.02) and ACP (P=0.05). Clinically, operations using SG compared with sinus-containing graft was associated with shorter aortic cross-clamp and cardiopulmonary bypass time (P<0.001, <0.001).
Conclusions: SG demonstrated hemodynamics and biomechanics most closely recapitulating those from the native root with significantly shorter intraoperative times compared with repair using sinus-containing graft. Future in vivo validation studies as well as correlation with comprehensive, comparative clinical study outcomes may provide additional invaluable insights regarding strategies to further enhance repair durability.},
issn = {2304-1021}, url = {https://www.annalscts.com/article/view/17045}
}